* ALL-IN-ONE BODY & FACE SCULPTING SYSTEM – Includes multiple interchangeable function heads: 6‑pole RF, negative pressure (medium/large), meridian brush, 80K fat‑burning ultrasound, red light microcurrent, micro‑electric laser board, and more. Perfect for slimming, skin tightening, lymphatic drainage, and facial rejuvenation in one professional device.
* CUSTOMIZABLE TREATMENT WITH DIGITAL CONTROLS – Features an easy‑to‑read LCD screen and intuitive interface. Adjust treatment time from 0 to 60 minutes and energy intensity across 10 levels. Negative pressure heads allow independent suction/release timing, giving you precise control for every client or personal use.
* ADVANCED MULTI‑TECHNOLOGY FOR EFFECTIVE RESULTS – Combines radio frequency (RF) heating, microcurrent, LED light therapy, and 80KHz ultrasonic cavitation to target stubborn fat, boost circulation, enhance product absorption, and promote skin firmness—all in a single device.
* PROFESSIONAL SAFETY FEATURES – Designed with safety in mind: the function heads must be kept moving during operation to prevent heat buildup, and the unit includes a pause button for immediate interruption. A stainless steel negative electrode patch ensures a complete circuit when using microcurrent functions, and strict contraindications (pregnancy, pacemakers, etc.) are clearly outlined.
GLOBAL COMPATIBILITY & EASY MAINTENANCE – Works with 110‑240V, 50/60Hz power supply—ideal for international use. Fuse replacement is simple (3A, 5x20mm) and daily inspections help ensure long‑term reliability. Backed by a 1‑year warranty on the main unit.
FREYARA 13in1 80K Multi-Function Fat Reduction Device combines advanced technologies including radio frequency, negative pressure, microcurrent, and LED light therapy. With multiple interchangeable function heads, it supports a wide range of treatments such as fat burning, lymphatic drainage, muscle toning, and facial lifting.
Note: This device is intended for beauty purposes only and is not a medical device.
Key Features
-
Multi-Function Compatibility: Supports facial and body treatments with interchangeable heads.
-
Adjustable Energy Levels: 10 adjustable intensity levels for personalized treatment.
-
Timer Control: Adjustable working time from 0 to 60 minutes.
-
User-Friendly Interface: LCD display with intuitive controls.
-
Safety First: Built-in safety features including suction adjustment and automatic shut-off.
-
Global Voltage Compatibility: Works with 110–240V, 50/60Hz power supply.
Included Function Heads and Their Uses
1. 6-Pole Heating Function Head
-
Application: Body contouring and fat reduction.
-
Function: Delivers RF energy to heat subcutaneous tissue, promoting fat metabolism and skin tightening.
2. Negative Pressure Heating Function Head (Medium & Large)
-
Application: Lymphatic drainage, cellulite reduction.
-
Function: Combines suction and release cycles to stimulate circulation and break down fat deposits.
-
Adjustable Settings: Suction and release timing can be independently adjusted.
3. Meridian Brush
-
Application: Full-body meridian massage.
-
Function: Stimulates energy pathways, improves circulation, and relieves muscle tension.
-
Additional Features: Adjustable LED light color and brightness.
4. 80K Fat-Burning Head
-
Application: Deep fat layer targeting.
-
Function: Uses high-frequency ultrasound to disrupt fat cells for effective fat reduction.
5. Red Light Micro Electric Head
-
Application: Skin rejuvenation and microcirculation.
-
Function: Combines red light therapy with microcurrent to enhance skin elasticity and glow.
6. Micro Electric Heating Transdermal Instrument
-
Application: Product absorption enhancement.
-
Function: Uses heat and microcurrent to help active ingredients penetrate deeper into the skin.
-
Requires: Stainless steel negative electrode patch for full circuit completion.
7. Micro Electric Laser Board
-
Application: Low-level laser therapy.
-
Function: Promotes cell regeneration and reduces inflammation.
8. Micro Electric Heating Scraping Stick
-
Application: Traditional Gua Sha-style massage.
-
Function: Combines heat and microcurrent for deep tissue stimulation and lymphatic drainage.
How to Use
Step-by-Step Instructions
-
Connect the Function Head
Attach the desired function head to the corresponding jack on the main unit. -
Plug in the Power Cord
Ensure the device is connected to a grounded power outlet (110–240V). -
Turn On the Device
Press the power switch. The indicator light and LCD screen will illuminate. -
Select Your Function Head
Choose the function head from the interface. The system will display the corresponding settings panel. -
Adjust Settings
-
Time: Default is 30 minutes. Adjust from 0 to 60 minutes.
-
Energy: 10 adjustable levels. Start low and increase gradually.
-
Suction/Release: Available for negative pressure heads.
-
Light: Adjust LED brightness and color where applicable.
-
-
Apply Product and Start
Apply a conductive gel or appropriate skincare product to the treatment area. Click “Start” and begin gliding the head over the skin. -
During Treatment
-
Keep the head moving—do not leave it stationary.
-
Monitor client comfort and adjust energy levels as needed.
-
Click “Pause” before moving or removing the head.
-
-
After Treatment
Click “Pause,” remove the head, and clean the device and skin area thoroughly.
Treatment Guidelines by Area
Thigh
-
Push from bottom up toward the groin.
-
Use counterclockwise circular motions.
-
Alternate with back-and-forth gliding.
Buttocks
-
Move toward the waist in lymphatic direction.
-
Use counterclockwise circles following muscle texture.
Back
-
Perform back-and-forth gliding.
-
Use circular motions while moving up and down.
Arms
-
Glide from the inner elbow to the armpit.
-
Stimulate lymph nodes with circular motions.
Face
-
Apply product evenly.
-
Use facial RF head from bottom up for 5–8 minutes following directional arrows.
Abdomen
-
Circle around the navel, starting small and moving outward.
-
Alternate clockwise and counterclockwise directions.
Important Safety Information
General Precautions
-
The device must be operated by trained personnel.
-
Inspect all wires and connections before use.
-
Do not apply external impact; move the device slowly and carefully.
-
If any abnormality occurs during operation, stop immediately and remove the handle from the skin.
Environmental Requirements
-
Use in a stable, well-ventilated indoor environment.
-
Keep at least 5 cm of space around the device for ventilation.
-
Avoid direct sunlight, high humidity, vibrations, and strong magnetic fields.
-
Do not use near radios, televisions, or microwave equipment.
Contraindications
Do not use this device on individuals who:
-
Are pregnant
-
Have heart conditions or use a pacemaker
-
Have cancer or have undergone major surgery
-
Have diabetes, epilepsy, or severe hypertension
-
Have skin wounds, allergies, or metal implants
-
Have gold wire implants in the face
Note: Facial surgery patients may use the device after 3 months, subject to professional assessment.